Fire rated
There are lots of choices in Deco Plus door and wall cladding design. Every single door matches with different themes and tastes of interior and architectural design. Our fire-rated door keep the balance between aesthetics, door function and safety. With the proprietary technology of our company which provides the best solutions to architects including door automation, acoustics and fire resistance with better service level than others, we aspire to provide the best exprience to customers and end users.
Fire Rated Product Reference
-/60/60 FRR - Wood veneer
-/60/60 FRR - Wood finish lamination
-/120/120 FRR - Wood lacquer
white matt finish
-/60/60 FRR - Timber Door
Finish: Formica (0928 Grey)
-/120/120 FRR - Timber Door
Glazing size: 100 x 100 (with S/S 304 plate for antibandit purpose)
Finish: Formica (6901 green)
-/60/60 FRR - Timber Door
Finish: Formica (6901 green)
-/120/120 FRR - Timber Door
Glazing size: 100 x 100
Finish: Formica (6901 green)
-/120/120 FRR - Timber Door
Glazing size: 200 x 200 (BSEN 356 (anti-bandit glass quanlity: P4A level)
Finish: Formica (6901 green)
-/120/120 FRR - Timber Door
Glazing size: 100 x 1672
Finish: Formica (6901 green)
Why Fire Rated Doors From DECO PLUS ?
01.
Flush and fully bonded door construction
● Flush version (for demanding architecture) or a Thick rebate version (for functional areas) with fully bonded fire resistance composite insert which increases leaf rigidity so the door closes with a rich sound.
02.
Elegant system in all functions
● Matching door appearance in all combinations with corner, block or profile frames. E.g. flush-fitting door leaf transition in double-leaf doors. It makes your planning for wall openings and passage widths simple.
03.
High quality and diverse finishes in various colors, textures and materials.
● Available in with powder coating/ galvanized finish/ DECO PLUS finishing solutions.
04.
Internal and external doors
● Both has different requirements for fire protection and performance characteristics e.g. wind load or water-tightness under heavy rain.
● For fire protection functions internal doors are subject to EN 1634, however, for external doors which exposed to wind and weather, are subject to EN 14351-1.
05.
Door furniture/ ironmongery solution
● For barrier-free passage, we provide automatic doors with various operative devices.
● Other door furniture such as lever handle set, hinges, closing devises, security bolts and other door access systems and technologies are also available upon request.
06.
The right solutions for your requirements:
● Fire-rated and smoke-tight doors
It is important to secure premises from life-threatening situations that is regulated heavily by fire-safety department in BS EN 1634. With DECO PLUS door solutions, doors are tested and officially approved.
● Acoustic-rated doors
Frequently specifying in function rooms that has a requirement of sound blocking by partitions, wall and doors. We could manufacture doors that can deliver acoustic values up to 44 dB.
● Security enhanced doors
Doors provided with additional break-in-resistant functions such as a (i) thick rebate version and (ii) an impact resistant glazing penal. Such doors are designed so that it withstand as long as possible in event of attempted unauthorized access and forced entry. There are diverse options regarding the surfaces, frames and other equipment for break-in-resistant doors.
STEEL FIRE-RATED DOOR
Both for fifire zones and for emergency exits,
as well as for important laboratories and
protected wards, fifire-proof safety is
extremely important. Selecting qualifified
fifire-rated doors is extremely important
when dealing with the possibility of fifires
DESIGN HIGHLIGHTS
• With 50 yeas of dedicated fifire-rated door production experience, Deco plus is a name synonymous with quality.
• Door leaves are fifilled with fifireproof board, ensuring exceptional fifire protection propertied; safe and environmentally friendly.
• Door leaves and frames are equipped with fifireproof expansion strips and heat seals. When fifires break out, they
effectively prevent the fifire and smoke from spreading, creating valuable time or escape.
• Multi-layer insulated fifire-proof glass ensures fifire-rated and heat insulation performance while bringing light through.
• An optional panic bar, an electromagnetic door stopper and other related accessories easily facilitate escapes,
evacuations, fifire control linkages and other functions.
• Deco plus ensures that all products are fully consistent with the tested and certifified samples!
Door closer with arm
Door closer with sliding rail
Anti-panic bar
TECHNICAL PARAMETERS
Leaf thickness
Leaf steel sheet thickness
Frame steel sheet thickness
Infifill
Acoustic insulation
Thermal insulation
Optional fifittings
Structural opening size
(max. W×H)
70 / 50mm
0.8 / 1.0* mm
1.5 / 2.0* mm
High-quality fifire-proof board
33-38 dB
1.8 –2.4 W/(m2∙K)
Glazing, anti-panic hardware, electromaganetic door stopper, etc.
Single-leaf door:1200×2500mm
Double-leaf door:2500×3000mm
* Structural opening of single-leaf door > 1000 x 2300 mm, structural opening of double-leaf door > 2000 x 2300 mm.
TECHNICAL
Door core
The core of a fifire door is fundamental to controlling the spread of fifire. Materials used in the manufacture of a fifire door have
to undergo extreme conditions at independent laboratories where they are subjected to controlled tests so that we can all
feel confifident.
The primary task of the core to is to resist fifire penetration. Once any flflames do begin to appear, the core must continue to
resist the fifire and burn at a slower rate.
Intumescent strip
Intumescent strips expand when heated
to create a seal between the door and
the frame thereby controlling the
transfer of smoke and noxious fumes
while restricting the air movement and
oxygen supply.
Vital to the control of fifire,
intumescent strips must be of the
correct specifification and must be
maintained in fifirst class condition. They
are usually fifitted after decoration to
avoid overpainting or varnishing which
would degrade their value so they are
generally supplied loose for fifitting on
site which must be by an experienced
installer.
Glazing options
Any glazing in a fifire door must perform
equal to the door core. It’s not just the
type and thickness of the glass that
matters, the size of each piece of glass,
the glazing gasket and the beads that
hold it in place are all critical to the
integrity of the door and must be fifitted
according to the test evidence. Gener
ally, glazing will be factory applied to
ensure full compliance.
Common Glazing Designs
Actual cut out sizes are shown, visible glass will be approx 15mm less on all
sides. Actual cut out height dimensions will be determined by the overall
height of the door.
STEEL SMOKE & FIRE-RATED DOOR (FRR 60/60)
Fire and heat insulation time 90 minutes
Fire Testing Standard: BS EN 1634-1:2008 and Smoke Control Testing
Standard: BS EN 1634-3:2004
Steel fifire-rated doors are infifilled with fifireproof board providing better fifire and
heat insulation performance. The fifireproof expansion strip at three sides of the
door leaf effectively block the spread of smoke. Door leaf can be fifitted with
fifireproof glazing and anti-panic functions when required, and is widely used in
the fifire areas of construction zones.
HC 90 CCC - 1
HC 90 CCC - 2
Class A
Steel fifire-rated door
HC 90 CCC
Standard Fittings
Fire and heat insulation time in hours
Leaf thickness
Leaf steel thickness
Frame steel thickness
Frame thickness
Infifill
Lock
Handle set
Hinge
1.5
70mm
0.8 / 1.0* mm
1.5 / 2.0* mm
114 / 150* mm
Fireproof board
Fireproof lock
Satin stainless steel D-110
3D-160 adjustable
Rebated door leaf
with flflush
appearance
Door leaf thickness
70 mm
All Steel
fifire-rated doors meet
CCC authentication.
Fire-rated
Class A
Sound insulation
38 dB
Locking bolts
Single-leaf door
Double-leaf door
2
4
Glazing
Fireproof glazing thickness
Max. area
Max. width
Max. height
35 mm
15% of the door area
≤ 280 mm
≤ 1000 mm
Door size
W x H
Single-leaf Double-leaf
Ordering width (min. - max.)
Ordering height (min. - max.)
600 – 1200 mm 1000 – 2500 mm
900 – 2500 mm 1000 – 3000 mm
* if the structural opening of single leaf door > 1000 x 2300 mm, if the structural opening of
double leaf door > 2100 x 2300 mm.
Thermal Insulation Value 1.8-1.9 W/(m² ·K)
Threshold:
Two versions of thresholds can be
delivered on request. Furthermore,
threshold improves sound insulation.
And the values of sound and thermal
insulation are tested when the door fifitted
with threshold with seal.
Threshold flflat
Threshold with seal
STEEL SMOKE & FIRE-RATED DOOR (FRR 120/120)
Fire and heat insulation time 60 / 30 minutes
Fire Testing Standard: BS EN 1634-1:2008 and Smoke Control Testing Standard:
BS EN 1634-3:2004
Fireproof expansion strip
Frame heat seal
Fireproof board
HCA 60 / 30 - 2
Flush door leaf
Door leaf thickness
50mm
All Steel
fifire-rated doors meet
CCC authentication.
High fifire-retardant
Class B
High fifire-retardant
Class C
Sound insulation
33 dB
Threshold:
Two versions of thresholds can be
delivered on request. Furthermore,
threshold improves sound insulation.
And the values of sound and thermal
insulation are tested when the door fifitted
with threshold with seal.
Threshold flflat
Threshold with seal
HCA 60 / 30 - 1